PT-DP Series Differential Pressure Transmitter
Category:
Features
The differential pressure transmitter PT-DP is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure. PT-DP outputs a 4 to 20 mA DC HART signal corresponding to the measured differential pressure. Other key features include quick response, remote set-up using communications, self-diagnostics and optional status output for pressure high/low alarm.
Specifications
| Specifications | |
| Accuracy | 0.05%FS, 0.075%FS, 0.1%FS |
| Pressure Type | Differertial Pressure |
| Response Time | ≤100ms |
| Medium | Liqud, Air, Steam |
| Longterm Stability | ≤0.03%FS/Year |
| Storage Temperature | -40°C~85°C |
| Ambient Temperature | -40°C~ 85°C, -20°C~ 65°C |
| Temperature Influence | ≤0.03%FS/10K |
| Power | 24V DC (Normal Working Voltage 15~42V) |
| Output | 40~20mA+HART |
| Electrical Interface | M20 x 1.5 F (Recommended) or 1/2" NPT F (Optional) |
| Diaphram Material | 316L, HC, Tartalum, 316L Gold Plated |
| Interface Material | 316L, HC |
| Shell Matenial | Aluminum Alloy, 316SS (Optional) |
Product Image & Drawing


Product Type Selection
|
Select Code (#) |
Order (Series) |
Diaphragm (F) |
Filling Liquid (Y) |
Rated Working Pressure (P) |
Static Pressure Chip (S) |
Display (D) |
Accuracy (A) |
Process Connection (C) |
Process Connection Accessories (K) |
Liquid Seal Material (E) |
Special Functions (G) |
Mounting Bracket (B) |
Explosion-proof (H) |
Number Location (N) |
Others (O) |
Electrical Interface (J) |
Range (R) |
| 1 | PT-DP- | SS 316L | Silicone | 0.2MPa (For R1) | NONE | None | ±0.05% | Without Relief Valve | None | (NBR) Nitrile Rubber | NONE | None | Typical | NONE | SS Watchcase | M20x1.5F (Normal) | 0/100Pa~1kPa (0/10~100mmH2O) (0/1~10mbar) |
| 2 | Hastelloy C | Fluorine | 7 MPa (For R1) | 40MPa (For R1) | LCD | ±0.075% | With Relief Valve | 1/2″ NPTF Stainless Steel Oval Flange | (FKM) Fluoro Rubber | Square Root Output | SS | NEPSI Instrinsically Safe Model | On the Nameplate | Low Voltage Version | 1/2" NPT F | 0/200Pa-6kPa (0/20~600mmH2O) (0/2-60mbar) | |
| 3 | SS 316L Gold-plating | 16MPa | OLED | ±0.1% | M20x1.5M SS T-connect | (PTFE) | Lightning Protection Function | Carbon Steel Galvanizing | NEPSI Flame-proof Type | Hanging Stainless Steel Sign | 0/400Pa~40kPa (0/40~4000mmH2O) (0/20~400mbar) | ||||||
| 4 | SS 316L Coating FEP | 25MPa | Oil Prohibition Treatment | 0/2.5kPa~250kPa (0/0.25~25mH2O) (0/25~2500mbar) | |||||||||||||
| 5 | Tartalum | 40MPa | 0/30kPa~3MPa (0/3~300mH2O) (0/0.3-30bar) | ||||||||||||||
| 6 | 0/100kPa~10MPa (0/10~1000mH2O) (0/1~100bar) |
Slide to see all
To Order PT-DP Differential Pressure Transmitter
| Select Code: | Series | F1 | Y1 | P1 | S2 | D2 | A1 | C1 | K2 | E1 | G2 | B2 | H1 | N2 | 01 | J1 | R1 |
| Order | PT-DP- | ||||||||||||||||
| Diaphragm | SS 316L | ||||||||||||||||
| Filling Liquid | Silicone | ||||||||||||||||
| Rated Working Pressure | 0.2MPa (For R1) | ||||||||||||||||
| Static Pressure Chip | 40MPa (For R1) | ||||||||||||||||
| Display | LCD | ||||||||||||||||
| Accuracy | ±0.05% | ||||||||||||||||
| Process Connection | Without Relief Valve | ||||||||||||||||
| Process Connection Accessories | 1/2" NPT F Stainless Steel Oval Flange | ||||||||||||||||
| Liquid Seal Material | (NBR) Nitrile Rubber | ||||||||||||||||
| Special Functions | Square Root Output | ||||||||||||||||
| Mounting Bracket | SS | ||||||||||||||||
| Explosion-proof | Typical | ||||||||||||||||
| Number Location | On the Nameplate | ||||||||||||||||
| Others | SS Watchcase | ||||||||||||||||
| Electrical Interface | M20x1.5F (Normal) | ||||||||||||||||
| Range | 0/100Pa~1kPa (0/10~100mmH20) (0/1~10mbar) |
Slide to see all
For the example indicated above, for product code PT-DP-F1Y1P1D2A1C1K2E1G2B2H1N2O1J1R1, the specs of the PT-DP Differential Pressure Transmitter selected are:
PT-DP Series, Diaphragm: SS 316L, Filling Liquid: Silicone, Rated Working Pressure: 0.2MPa (For R1), Static Pressure Chip: 40MPa (For R1), Display: LCD (-20°C), Accuracy: +0.05%, Process Connection: Without Relief Valve,Process Connection Accessories: 1/2" NPT F Stainless Steel Oval Flange, Liquid Seal Material: (NBR) Nitrile Rubber, Special Functions: Square Root Output, Mounting Bracket: SS, Explosion-proof: Typical, Number Location: On the Nameplate, Others: SS Watchcase, Electrical Interface: M20 × 1.5 F (Normal), Range: 0/100Pa~1kPa (0/10~100mmH2O) / (0/1-10mbar)
Keywords: PT-DP Series Differential Pressure Transmitter
Online Consulting
Please ensure the information is filled out accurately and your communication remains open. We will get in touch with you as soon as possible. Thank you!
You May Also Love