SH-VA / SA / FA 10, 20, 30 Series Glass Tube Flowmeter
Features
VA / SA / FA10, 20, 30 glass tube flowmeter has three types of connection, they are threaded type (G10, 20, 30 types), hose type (R10, 20, 30 types), flange type (F10, 20, 30 types). It is divided into conventional type (measuring general noncorrosive fluid) and corrosion resistant type (measuring corrosive fluid). The meter is featured with compactness, light structure, nice figure, convenient maintenance, safe and reliability, easy installation. The flange of F10, 20, 30 types can rotate to be aligned with the pipe holes on site. VA/SA/FA10, 20, 30 glass tube flowmeters can substitute the glass tube flowmeters installed on the complete production lines imported, are widely used in chemical industry, light industry, pharmacy, food industry, papermaking, environment protection, measuring, testing and scientific research institutes etc. to measure the flow rate of single phase non pulase fluid (liquid or gas).
Outline Size and Connection
- VA / SA / FA 10

Unit: mm
| DN (mm) | axb | VA10 | SA10 | FA10 | |||||||
| L | C | Screw | L | C | D | L | C | D | E | ||
| DN15 | 26x230mm | 408mm | 52mm | G 1/2" | 400mm | Φ17mm | Φ43mm | 310mm | Φ65mm | Φ95mm | 4-Φ14mm |
| G 3/8" | |||||||||||
| NPT 1/2" | |||||||||||
| DN25 | 32x230mm | 414mm | 75mm | G 1" | 450mm | Φ27mm | Φ60mm | 310mm | Φ85mm | Φ115mm | 4-Φ14mm |
| G 3/4" | |||||||||||
| NPT 1" | |||||||||||
| DN40 | 40x230mm | 424mm | 92mm | G 1 1/2" | 450mm | Φ44mm | Φ78mm | 310mm | Φ110mm | Φ145mm | 4-Φ18mm |
| NPT 1 1/2" | |||||||||||
| DN5 | 50x230mm | 426mm | 116mm | G 2" | 450mm | Φ54mm | Φ98mm | 310mm | Φ125mm | Φ160mm | 4-Φ18mm |
| NPT 2" | |||||||||||
- VA / SA / FA 20

Unit: mm
| DN (mm) | VA20 | SA20 | FA20 | |||||||
| L | C | Screw | L | C | D | L | C | D | E | |
| DN15 | 375mm | Φ58mm | G 1/2" | 400mm | Φ17mm | Φ58mm | 425mm | Φ65mm | Φ95mm | 4-Φ14mm |
| G 3/8" | ||||||||||
| NPT 1/2" | ||||||||||
| DN25 | 375mm | Φ74mm | G 1" | 450mm | Φ27mm | Φ74mm | 425mm | Φ85mm | Φ115mm | 4-Φ14mm |
| G 3/4" | ||||||||||
| NPT 1" | ||||||||||
| DN40 | 375mm | Φ92mm | G 1 1/2" | 450mm | Φ44mm | Φ92mm | 425mm | Φ110mm | Φ145mm | 4-Φ18mm |
| NPT 1 1/2" | ||||||||||
| DN5 | 375mm | Φ112mm | G 2" | 450mm | Φ54mm | Φ112mm | 425mm | Φ125mm | Φ160mm | 4-Φ18mm |
| NPT 2" | ||||||||||
- VA / SA / FA 30

Unit: mm
| DN (mm) | axb | VA30 | SA30 | FA30 | |||||||
| L | C | Screw | L | C | D | L | C | D | E | ||
| DN15 | 28x230mm | 375mm | 52mm | G 1/2" | 400mm | Φ17mm | Φ43mm | 310mm | Φ65mm | Φ95mm | 4-Φ14mm |
| G 3/8" | |||||||||||
| NPT 1/2" | |||||||||||
| DN25 | 32x230mm | 375mm | 75mm | G 1" | 450mm | Φ27mm | Φ60mm | 310mm | Φ85mm | Φ115mm | 4-Φ14mm |
| G 3/4" | |||||||||||
| NPT 1" | |||||||||||
| DN40 | 45x230mm | 375mm | 92mm | G 1 1/2" | 450mm | Φ44mm | Φ78mm | 310mm | Φ110mm | Φ145mm | 4-Φ18mm |
| NPT 1 1/2" | |||||||||||
| DN5 | 55x230mm | 375mm | 116mm | G 2" | 450mm | Φ54mm | Φ98mm | 310mm | Φ125mm | Φ160mm | 4-Φ18mm |
| NPT 2" | |||||||||||
Technical Parameter
| DN (mm) |
Normal Type |
Anti-corrosion Type |
Flow Range |
Pressure Loss (Pa) |
Allowed Measuring Fluid Condition |
Accuracy | ||
| Water (20°C) L/h |
Air (20°C/101325Pa) m/h |
Pressure (MPa) | Temperature | |||||
| 15 | VA10/20/30-15 SA10/20/30-15 FA10/20/30-15 |
VA10/20/30-15F SA10/20/30-15F FA10/20/30-15F |
10~100 16~160 25~250 40~400 63~630 |
0.12~1.2 0.2~2 0.3~3 0.5~5 0.8~8 1.2~12 2~20 |
1000 1100 1200 1700 2000 2500 3000 |
≤1.0 | -20+120°C | ±2.5% |
| 25 | VA10/20/30-25 SA10/20/30-25 FA10/20/30-25 |
VA10/20/30-25F SA10/20/30-25F FA10/20/30-25F |
63~630 100~1000 160~1600 250~2500 |
2~20 3~30 5~50 6~60 |
2800 4000 5000 6000 |
|||
| 40 | VA10/20/30-40 SA10/20/30-40 FA10/20/30-40 |
VA10/20/30-40F SA10/20/30-40F FA10/20/30-40F |
160~1600 250~2500 400~4000 |
5~50 8~80 12~120 |
3400 4000 5000 |
≤0.9 | ||
| 50 | VA10/20/30-50 SA10/20/30-50 FA10/20/30-50 |
VA10/20/30-50F SA10/20/30-50F FA10/20/30-50F |
400~4000 630~6300 100~1000 |
12~120 20~200 30~300 |
4800 6500 8500 |
≤0.7 | ||
Notes:
The pressure of the medium in the flowmeter, for the liquid shall be at least two times of the pressure loss for the gas must be exceed 5 times of pressure loss.
Accuracy class 1.5 can be ordered in speciality.
The maximal flow of corrosion resistant PTFE floater is one class lower than the conventional type.
The model of anti-corrosion type lining PTFE only for FA10 and FA30 series, model show as: 10-( )F0, 30-( )F0.
Medium Touching Parts Materia
| Parts Material Model | VA10-( ) | VA10-( )F | SA10-( ) | SA10-( )F | FA10-( ) | FA10-( )F |
| VA20-( ) | VA20-( )F | SA20-( ) | SA20-( )F | FA20-( )F | ||
| VA30-( )F | SA30-( )F | FA30-( )F | ||||
| Float | 304SS | |||||
| Upper & Lower Stop | Nylon | Fluoroplastics | Nylon | Luoroplastics | Nylon | Fluoroplastics |
| Seals | Nitrile Rubber | Fluororubber | Nitrile Rubber | Fluororubber | Nitrile Rubber | Fluororubber |
| Screw Connection | Carbon Steel (Zinc Plating) |
304SS | ||||
| Connection | Aluminium (G20) | 304SS | ||||
| Hose Connection | AI | 304SS | ||||
| Flange Connection | A | 304SS | ||||
Note: Other materials are customized.
Keywords: SH-VA / SA / FA 10, 20, 30 Series Glass Tube Flowmeter