SH-LUG Series Vortex Flowmeter
Desription
The vortex flowmeter operates on the basis of Karman vortex street principle.
If put a vertical cylinder in flow fluid, during the range of Reynolds number will alternate to form a regular vortex behind the cylinder two sides, named as Karman vortex street. The direction of vortex street is inward, up will form a clockwise rotation, down will form a counter-clockwise rotation, the frequency in single side in proportion to flowrate, in inverse proportion to the diameter of vortex producer, the relationship of them as following: f = St x v / d
In the formula: St-Jack straw Hal number; f-frequency product by single side vortex; v-flowrate; d-diameter.
Instrument parameters K: a ratio of separation, pulse amount of vortex to the volume amount: K= N / V
In the formula: K-instrument coefficient (pulse 1/m³); N-pulse number (time); V-volume amount
The relationship between the vortex separation frequency and liquid flow is as follows: f=K x Q
In the formula: f-frequency (time); Q-flow(m³/h)
By testing the vortex separation frequency, the liquid flow in the pipe can be measured.
Product Type Selection
| Model | Instruction | |||||||
| SH-LUG- | ___ | ___ | ___ | ___ | ___ | ___ | ||
| Karman Vortex Street | ||||||||
| Stress Type Testing | ||||||||
| Measuring Ways |
1 | Flange Connection (GB9119-2000) | ||||||
| 2 | Clamp Flange (Equip with Flange and Bolts in Factory) | |||||||
| Medium | 1 | Both for Gas and Liquid | ||||||
| 2 | Liquid | |||||||
| 3 | Gas | |||||||
| 4 | Steam | |||||||
| Diameter | 2 | DN25 | ||||||
| 4 | DN40 | |||||||
| 5 | DN50 | |||||||
| 8 | DN80 | |||||||
| 10 | DN100 | |||||||
| 15 | DN150 | |||||||
| 20 | DN200 | |||||||
| 25 | DN250 | |||||||
| 30 | DN300 | |||||||
| Operation Condition | Blank | Normal Type | ||||||
| B | Instrinsic Safety, iallCT6 | |||||||
| Signal Output | P | Voltage Pulse, 24V Power;Hand Operator and Digital Control Meter Is Optional | ||||||
| S | Pulse, 4~20mA, On-site, 24V Power; Optional Input Ports: HART, Temp. (PT100), Pressure Sensor, Pressure Transmitter | |||||||
| D | On-site, without Any Display, Lithium Battery;Without Any Input Ports | |||||||
| Structure | F | Separated Type | ||||||
| Z | Integrated Type | |||||||